like 3 comments  share
Rob Packard
Ship & Print Your FDA eCopy
April 2017
IFU Validation and Post-Market Surveillance
2 min reading time

Some companies ask physicians that helped them with product development review draft IFUs. However, these physicians are already familiar with your product, your company and they are highly skilled in the specific procedures your device will be used for. After your own experts have make their final edits to your draft IFU, you now need a “fresh set of eyes.” The best approach is to validate the effectiveness of your IFU with potential users that don’t know you or your company. If your product requires animal performance testing or human clinical studies, you could use these studies to validate your IFU. However, I recommend conducting a simulated use study prior to conducting animal or human studies. Conducting a simulated use study prior to animal and human studies can prevent deviations from your documented protocols that were caused by inadequate review of the IFUs.

After your IFU is validated, and you obtain regulatory approval for your product, you may still need to make updates to your IFUs as new risks are identified. In order to decide whether you need to update your IFUs you need to gather post-market surveillance data.

Post-market surveillance is not just asking customers if they are satisfied. You need to continue to monitoring adverse event databases, your own complaint database and any service records to determine if there are any new risks and to verify that the risks you identified were accurately estimated with regard to severity and probability of occurrence of harm. In fact, clinical studies and PMS are the only way you can gather data regarding probability of occurrence of harm. When you design your post-market surveillance questions, make sure you include questions specifically targeting the residual risks you identify in your IFU. You should also ask, “What indications do you use this device for. Specifically, please identify the intended diagnosis, treatment and patient populations.” This wording is more effective than asking if a physician is using your product “off label.”

If you want to learn more about using a risk-based approach to developing IFUs, validating IFUs and performing post-market surveillance to monitor the effectiveness of your IFU, then visit my blog posting from earlier today (http://www.medicaldeviceacademy.com/blog) or the following webinar page to register for our webinar on Friday, April 21:

http://medicaldeviceacademy.com/IFU-validation-webinar/

source: https://www.linkedin.com/groups/2070960/2070960-6257949810855288836

Marked as spam
Posted by Rob Packard
Asked on April 12, 2017 12:00 am
450 views
  • Follow
  • Unfollow
  • Report spam
like 3 comments  share

Meet your next client here. Join our medical devices group community.

Private answer
Kiran SM Thanks Robert Packard : I like the open-ended question during the post-market surveillance survey that you have shared.
Marked as spam
like
  • Report spam
Private answer
Jean-Jerome Dubus good tips IFU related to user requirements and later post market surveillance. so clear. IFU is pivotal document and needs for solid process.
Marked as spam
like
  • Report spam
Private answer
Edwin Bills, ASQ Fellow, RAC IFU Validation is a part of Human Factors (Usability) Validation and as Robert has stated, needs to be validated by those not part of the development of the device. FDA guidance and the Usability Standard IEC 62366-1 provide guidance on validation and IFU is a part of that process.
Marked as spam
like
  • Report spam
« Back to Previous Page
Ask a Question
Leave a Comment

We still use LinkedIn to access our site because it’s the only way to “pull in” your LinkedIn photo, name, and hyperlink to your profile page, all vital in building your professional network. When you log in using LinkedIn, you are giving LinkedIn your password, not me. I never see nor store your LinkedIn credentials.

Stay connected with us.

By signing up you are agreeing to our Privacy Policy.

Categories

  • Capital/Investment
    • Business Model
    • Funding
  • Careers
  • Design/Devel
    • Design
    • Development
    • Human Factors
    • Labeling
    • Material Selection
    • R&D
    • Trials and Post-Market
  • Featured
  • Industry
    • Announcements
    • Device Tax
    • Hospital and Health Care
    • Innovation
    • Medtech
  • LinkedIn, etc.
  • Markets
    • Africa
    • Americas
    • Asia
    • Australia
    • Europe
  • Regulating
    • CE Marking
    • EU
    • FDA
    • FDA/EU etc.
    • Notified Bodies
    • Quality
    • Regulatory
  • Selling
    • Distribution
    • Intellectual Property
    • Marketing/Sales
    • Reimbursement
  • Worth bookmarking!
Feature your job here.
logo

Companion to LinkedIn's 350,000 member community

  • Contact
  • Medical Device Marketing
  • In Memoriam
  • Medical Device Conference

The Medical Devices Group   |   Copyright © 2025 Terms, Conditions & Privacy

Medical Devices Group
Powered by  GDPR Cookie Compliance
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

If you disable this cookie, we will not be able to save your preferences. This means that every time you visit this website you will need to enable or disable cookies again.